LC_X80 Basic Serial Command Functional Specifications
19/23
7 Status Read Command
7.1 Format
PC issues a command in the following format.
“CR” Command [CR]
Command: one character (See Status Read Command Table)
When projector receives an appropriate command, it returns the required data in string.
Required Data [CR]
Required Data: string (See Status Read Command Table)
When the received data cannot be decoded, the projector returns “?” [CR] is returned.
7.2 Transfer Example
Geting Input mode information of projector by Basic Commands.
Command (issue current input mode command)
PC Projector “C” “R “1” CR
Projector PC “1” CR
―――→ Response
(A few ms 5 s)
(Indicating Computer 1 is selected)
7.3 Status Read Command
Command
CR0” [CR]
Detail Get the projector’s operating status
Acceptable “%1” [CR]
%1
”00” = Power ON
“80” = Standby
“40” = Countdown in process
“20” = Cooling Down in process
“10” = Power Failure
“28” = Cooling Down in process due to Abnormal Temperature
“88” = Standby after Cooling Down due to Abnormal Temperature
“24” = Power-Save Cooling Down in process
“04” = Power Save
“21” = Cooling Down in process after OFF due to Lamp Failure
“81” = Standby after Cooling Down due to Lamp Failure
Response
Unacceptable
“?” [CR]
Details for Response
“00” [CR]
Status: Power ON
Normal image is on-screen.